{"id":3960,"date":"2019-04-18T18:03:30","date_gmt":"2019-04-18T16:03:30","guid":{"rendered":"https:\/\/www.epsilon-composite.com\/?post_type=produits&#038;p=3960"},"modified":"2026-08-17T11:16:21","modified_gmt":"2026-08-17T09:16:21","slug":"truss-structures","status":"publish","type":"produits","link":"https:\/\/www.epsilon-composite.com\/en\/our-products\/truss-structures","title":{"rendered":"Carbon fiber structural trusses"},"content":{"rendered":"\n<h4 class=\"wp-block-heading\">Stiffness + light weight<\/h4>\n\n\n\n<h2 class=\"wp-block-heading\">Lightweight structures with optimal stiffness <\/h2>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"alignright\"><img decoding=\"async\" width=\"490\" height=\"150\" src=\"https:\/\/www.epsilon-composite.com\/wp-content\/uploads\/2019\/04\/structure-trellis-visuel1.jpg\" alt=\"\" class=\"wp-image-3375\" srcset=\"https:\/\/www.epsilon-composite.com\/wp-content\/uploads\/2019\/04\/structure-trellis-visuel1.jpg 490w, https:\/\/www.epsilon-composite.com\/wp-content\/uploads\/2019\/04\/structure-trellis-visuel1-250x77.jpg 250w, https:\/\/www.epsilon-composite.com\/wp-content\/uploads\/2019\/04\/structure-trellis-visuel1-450x138.jpg 450w, https:\/\/www.epsilon-composite.com\/wp-content\/uploads\/2019\/04\/structure-trellis-visuel1-412x126.jpg 412w\" sizes=\"(max-width: 490px) 100vw, 490px\" \/><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\">Compared to a solid monolithic beam, truss beams provide a solution with an unparalleled stiffness\/weight ratio, thanks to the assembly of standard tubes.<br>To go even further than existing metal solutions, we have transposed this technology to carbon composite. The tubes are lighter and stiffer than their metal counterparts, meaning it is therefore possible to <strong>push the limits with ultra-light XXL structures that are corrosion-resistant<\/strong>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">By applying its experience in mechanical dimensioning (static\/dynamic) and structural assemblies, Epsilon Composite offers <strong>well-developed solutions<\/strong> to create structural trusses in composite materials.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter is-resized\"><img decoding=\"async\" width=\"1280\" height=\"278\" src=\"https:\/\/www.epsilon-composite.com\/wp-content\/uploads\/2019\/04\/structure-treillis-1.jpg\" alt=\"\" class=\"wp-image-3497\" style=\"width:960px;height:209px\" srcset=\"https:\/\/www.epsilon-composite.com\/wp-content\/uploads\/2019\/04\/structure-treillis-1.jpg 1280w, https:\/\/www.epsilon-composite.com\/wp-content\/uploads\/2019\/04\/structure-treillis-1-250x54.jpg 250w, https:\/\/www.epsilon-composite.com\/wp-content\/uploads\/2019\/04\/structure-treillis-1-450x98.jpg 450w, https:\/\/www.epsilon-composite.com\/wp-content\/uploads\/2019\/04\/structure-treillis-1-768x167.jpg 768w, https:\/\/www.epsilon-composite.com\/wp-content\/uploads\/2019\/04\/structure-treillis-1-1100x239.jpg 1100w\" sizes=\"(max-width: 1280px) 100vw, 1280px\" \/><\/figure>\n<\/div>\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter is-resized\"><img decoding=\"async\" width=\"1280\" height=\"303\" src=\"https:\/\/www.epsilon-composite.com\/wp-content\/uploads\/2019\/04\/structure-treillis-2.jpg\" alt=\"\" class=\"wp-image-3499\" style=\"width:960px;height:227px\" srcset=\"https:\/\/www.epsilon-composite.com\/wp-content\/uploads\/2019\/04\/structure-treillis-2.jpg 1280w, https:\/\/www.epsilon-composite.com\/wp-content\/uploads\/2019\/04\/structure-treillis-2-250x59.jpg 250w, https:\/\/www.epsilon-composite.com\/wp-content\/uploads\/2019\/04\/structure-treillis-2-450x107.jpg 450w, https:\/\/www.epsilon-composite.com\/wp-content\/uploads\/2019\/04\/structure-treillis-2-768x182.jpg 768w, https:\/\/www.epsilon-composite.com\/wp-content\/uploads\/2019\/04\/structure-treillis-2-1100x260.jpg 1100w\" sizes=\"(max-width: 1280px) 100vw, 1280px\" \/><figcaption class=\"wp-element-caption\">Example of a 3D model and calculation of the deformation under beam load<\/figcaption><\/figure>\n<\/div>\n\n\n<h2 class=\"wp-block-heading\">Technical options<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">For metallic truss beams, tubes are generally assembled by welding. We have developed several solutions more adapted to composite materials, which meet very specific needs:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Assembled beams that cannot be dismantled with glued connection parts<\/strong>: these connections can be made from composite or metal and offer the best compromise between weight, stiffness and cost.<\/li>\n\n\n\n<li><strong>100% composite beams that cannot be dismantled with overmoulded or draped connections<\/strong>: these solutions can be optimised further in terms of weight, but industrialising them can be more expensive.<\/li>\n\n\n\n<li><strong>Beams that can be dismantled by connecting rods<\/strong>: solutions that cannot be optimised as much in terms of weight, which makes assembly, transport and repair easier.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">We offer several geometries of structural trusses to adapt to your specifications and the available space: 2D &#8220;ladders&#8221;, triangular trusses, square section beams, etc.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Depending on your requirements (stiffness requirements, weight savings, fire resistance, impact resistance, etc.), our experts will guide you towards an optimised solution.<\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter\"><img decoding=\"async\" width=\"854\" height=\"357\" src=\"https:\/\/www.epsilon-composite.com\/wp-content\/uploads\/2019\/08\/Poutre-treillis-jonctions-m\u00e9talliques-coll\u00e9es.jpg\" alt=\"\" class=\"wp-image-3675\" srcset=\"https:\/\/www.epsilon-composite.com\/wp-content\/uploads\/2019\/08\/Poutre-treillis-jonctions-m\u00e9talliques-coll\u00e9es.jpg 854w, https:\/\/www.epsilon-composite.com\/wp-content\/uploads\/2019\/08\/Poutre-treillis-jonctions-m\u00e9talliques-coll\u00e9es-250x105.jpg 250w, https:\/\/www.epsilon-composite.com\/wp-content\/uploads\/2019\/08\/Poutre-treillis-jonctions-m\u00e9talliques-coll\u00e9es-450x188.jpg 450w, https:\/\/www.epsilon-composite.com\/wp-content\/uploads\/2019\/08\/Poutre-treillis-jonctions-m\u00e9talliques-coll\u00e9es-768x321.jpg 768w\" sizes=\"(max-width: 854px) 100vw, 854px\" \/><\/figure><\/div>\n\n\n\n<div style=\"height:2em\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div style=\"height:2em\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Related content<\/h2>\n\n\n\n<div class=\"wp-block-group is-nowrap is-layout-flex wp-container-core-group-is-layout-8f761849 wp-block-group-is-layout-flex\"><div id=\"post-9194\" class=\"item-produit post-9194 etudedecas type-etudedecas status-publish has-post-thumbnail hentry etudedecas-filter-aeronautique\" role=\"article\">\n<figure class=\"redbox\" id=\"post-9194\" >\n\t\t\t\n\t\t\n\t\t\t<img decoding=\"async\" width=\"612\" height=\"474\" src=\"https:\/\/www.epsilon-composite.com\/wp-content\/uploads\/2019\/08\/ppt-FW-612x474.png\" class=\"attachment-medium-carre size-medium-carre wp-post-image\" alt=\"LCA60T \u2013 HEAVY-LIFT AIRSHIP\" \/>\t\t\n\n\t\t\t\t\t<figcaption>\n\t\t\t<h2>LCA60T \u2013 HEAVY-LIFT AIRSHIP<\/h2>\n\t\t\t\n\n\t\t\t<\/figcaption>\n\t\t\t<a href=\"https:\/\/www.epsilon-composite.com\/en\/case-study\/lca60t-heavy-lift-airship\">Voir plus<\/a>\n\t\t\t<span><\/span>\n<\/figure>\n<\/div>\n\n\n<div id=\"post-13359\" class=\"item-produit post-13359 etudedecas type-etudedecas status-publish has-post-thumbnail hentry\" role=\"article\">\n<figure class=\"redbox\" id=\"post-13359\" >\n\t\t\t\n\t\t\n\t\t\t<img decoding=\"async\" width=\"304\" height=\"280\" src=\"https:\/\/www.epsilon-composite.com\/wp-content\/uploads\/2022\/12\/Sans-titre-304-\u00d7-280-px.png\" class=\"attachment-medium-carre size-medium-carre wp-post-image\" alt=\"Carbon fiber lattice structure for machine gantries\" srcset=\"https:\/\/www.epsilon-composite.com\/wp-content\/uploads\/2022\/12\/Sans-titre-304-\u00d7-280-px.png 304w, https:\/\/www.epsilon-composite.com\/wp-content\/uploads\/2022\/12\/Sans-titre-304-\u00d7-280-px-250x230.png 250w\" sizes=\"(max-width: 304px) 100vw, 304px\" \/>\t\t\n\n\t\t\t\t\t<figcaption>\n\t\t\t<h2>Carbon fiber lattice structure for machine gantries<\/h2>\n\t\t\t\n\n\t\t\t<\/figcaption>\n\t\t\t<a href=\"https:\/\/www.epsilon-composite.com\/en\/case-study\/case-study-carbon-fiber-lattice-structure-truss-machine\">Voir plus<\/a>\n\t\t\t<span><\/span>\n<\/figure>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Stiffness + light weight Lightweight structures with optimal stiffness Compared to a solid monolithic beam, truss beams provide a solution with an unparalleled stiffness\/weight ratio, thanks to the assembly of standard tubes.To go even further than existing metal solutions, we have transposed this technology to carbon composite. The tubes are lighter and stiffer than their [&#8230;] <\/p>\n<p><a class=\"btn icon icon-plus\" href=\"https:\/\/www.epsilon-composite.com\/en\/case-study\/case-study-carbon-fiber-lattice-structure-truss-machine\"><span>Read more<\/span><i><\/i><\/a><\/p>\n","protected":false},"featured_media":11093,"template":"","meta":{"_acf_changed":false,"_monsterinsights_skip_tracking":false,"_uf_show_specific_survey":0,"_uf_disable_surveys":false,"footnotes":""},"cat_produits":[69,67],"class_list":["post-3960","produits","type-produits","status-publish","has-post-thumbnail","hentry","cat_produits-aerospace-en","cat_produits-industries-en","aerospace-en","industries-en"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.epsilon-composite.com\/en\/wp-json\/wp\/v2\/produits\/3960","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.epsilon-composite.com\/en\/wp-json\/wp\/v2\/produits"}],"about":[{"href":"https:\/\/www.epsilon-composite.com\/en\/wp-json\/wp\/v2\/types\/produits"}],"version-history":[{"count":2,"href":"https:\/\/www.epsilon-composite.com\/en\/wp-json\/wp\/v2\/produits\/3960\/revisions"}],"predecessor-version":[{"id":23912,"href":"https:\/\/www.epsilon-composite.com\/en\/wp-json\/wp\/v2\/produits\/3960\/revisions\/23912"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.epsilon-composite.com\/en\/wp-json\/wp\/v2\/media\/11093"}],"wp:attachment":[{"href":"https:\/\/www.epsilon-composite.com\/en\/wp-json\/wp\/v2\/media?parent=3960"}],"wp:term":[{"taxonomy":"cat_produits","embeddable":true,"href":"https:\/\/www.epsilon-composite.com\/en\/wp-json\/wp\/v2\/cat_produits?post=3960"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}